STRATUS
INSTALLATION
30 Barnet Boulevard
New Bedford, MA 02745
(508) 995-2200
PROPER INSTALLATION IS IMPORTANT. IF YOU NEED ASSISTANCE, CONSULT A CONTRACTOR, ELECTRICIAN
OR TELEVISION ANTENNA INSTALLER (CHECK WITH YOUR LOCAL BUILDING SUPPLY, OR HARDWARE STORE
FOR REFERRALS). TO PROMOTE CONFIDENCE, PERFORM A TRIAL WIRING BEFORE INST TION.ALLA
1
Remove the cover of the Humidity sensor to gain
access to the holes on the upper left and lower
right side of the sensor. Mount the sensor to the
wall with two wood screws. The sintered bronze
sensor house should face toward the ground.
Select a location that is protected from direct
sunlight. (A northern exposure about six feet
off the ground with good air flow will give the
best results.)
CAULK
8"
MIN
COVER
WOOD SCREWS
2
Form a drip loop with the wire that
is at least eight inches below the
exit point of entry. Anchor any
exposed wire with insulated cable
clips. Run the wire through the
building to the location where the
indicator will be located. Caulk any
holes when done
DRIP
LOOP
SENSOR
BRONZE
SENSOR
HOUSE
CABLE
CLIP
Feed the AC adaptor’s cord to the rear of the indicator.
Connect the two wires of the AC adapter cord to the
indicator using the brass nuts supplied in the hardware
pack. The polarity does not matter.
3
1
2
3
TEST POINT 1
Test
Point:
INDICATOR
AC
ADAPTER
NUTS
BRASS
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - INSTALLATION

STRATUSINSTALLATION30 Barnet BoulevardNew Bedford, MA 02745(508) 995-2200PROPER INSTALLATION IS IMPORTANT. IF YOU NEED ASSISTANCE, CONSULT A CONTRACTO

Strona 2 - INSTALLATION (CONT.)

STRATUSINSTALLATION (CONT.)5FEED-THRU-HOLECABLE-HOLECABLESSCREWWOODPANELWALLSCREWMount the brass instrument directly over the cable holeused to route

Strona 3 - OPERATION

OPERATIONIt can take 12-24 hours for the humidity sensor toacclimate to its surroundings and reflect accuratereadings. Before reading your Hygrometer,

Strona 4 - HEAT INDEX

STRATUSINFORMATION ON HUMIDITYDew point is the temperature at which a parcel of air reaches its saturation point and can no longerhold water in the va

Strona 5 - TROUBLESHOOTING

STRATUSTROUBLESHOOTINGUnplug theAC Adapter.Remove theinstrument fromthe wall.Disconnect the AC adapter from the indicator and connect itto an AC voltm

Strona 6 - TROUBLESHOOTING (CONT.)

STRATUSTROUBLESHOOTING (CONT.)To test the sensor connect a DC voltmeter to terminals#2 and #3. Terminal #2 is the ground terminal and #3the positive o

Strona 7

IMPORTANT ADDITIONAL INFORMATION Components: Along with the indicator, the following components are included with this instrument:

Strona 8 - Common Causes:

30 SAMUEL BARNET BOULEVARD  NEW BEDFORD, MASSACHUSETTS 02745 U.S.A. TEL. 508.995.2200  WWW.MAXIMUM-INC.COM  FAX 800.989.2580 Electrical Damage

Komentarze do niniejszej Instrukcji

Brak uwag